[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]

Re: 7747 spark control questions.



Depends on reference or initial timing value at 0x009.  If bias is at
10 Dizz base at 9, and static angle is 9, spark table is only 10 deg
biased.
Shannen

Programmer wrote:
> 
> You're at 9 BTC with the EST disconnected ? That adds another 10 with
> EST connected. You're going to be close to 35-40 BTC hot idle.
> Lyndon.
> -----Original Message-----
> From: Reid Bishop <rbish@ibm.net>
> To: gmecm@diy-efi.org <gmecm@diy-efi.org>
> Date: October 17, 2000 12:52 AM
> Subject: RE: 7747 spark control questions.
> 
> >>>Dissies are set "0" with the EST disconnected. The bins should show main
> >>>spark bias at 10 degrees.
> >
> >Really?  Hmmmm... my 4.3 dist is set to 9 BTC, and I my spark bias is set
> to
> >10.  I could still use more advance throughout the curve, but not working
> >that yet.
> >
> >Are 4.3's the exception to this rule?
> >
> >---------------------------------------------------------------------------
> -
> >To unsubscribe from gmecm, send "unsubscribe gmecm" (without the quotes)
> >in the body of a message (not the subject) to majordomo@lists.diy-efi.org
> >
> 
> ----------------------------------------------------------------------------
> To unsubscribe from gmecm, send "unsubscribe gmecm" (without the quotes)
> in the body of a message (not the subject) to majordomo@lists.diy-efi.org
----------------------------------------------------------------------------
To unsubscribe from gmecm, send "unsubscribe gmecm" (without the quotes)
in the body of a message (not the subject) to majordomo@lists.diy-efi.org